Series 8500 Thermo-Anemometers

Model 8585 Features:

  • Measures velocity, volume, temperature and humidity without ever changing probes.
  • Stores over 999 data points and can take continuous measurements in a datalogging mode
  • Prints in real-time to a lightweight MicroPrinter, or downloads stored data to a windows software application
  • Data logs on a variable time base for IAQ studies
  • Recalls useful statistics such as max., min., and average
  • Also measures wet bulb and dew point

    Model 8585 Specifications:

    TEMPERATURE

  • Range: 0 to 140°F (-17.8 to 60°C)
  • Accuracy: ±0.5°F (±0.3°C)
  • Resolution: 0.1°F (0.1°C)

    RELATIVE HUMIDITY

  • Range: 0 to 95% RH
  • Accuracy: ±3% RH
  • Resolution: 0.1% RH

    WET BULB TEMPERATURE

  • Range: 40 to 140°F (5 to 60°C)
  • Resolution: 0.1°F (0.1°C)

    DEW POINT TEMPERATURE

  • Range: 2 to 120°F (-15 to 49°C)
  • Resolution: 0.1°F (0.1°C)

    DATA LOGGING CAPABILITIES

  • Storage Range: Up to 1871 samples, up to 285 test IDs
  • Intervals: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 15, 20, 25, or 30 seconds; 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 15, 20, 25, 30, or 60 minutes

    Model 8570 Features:

  • Designed for ease of use and rapid checking of air flow conditions.
  • Measures velocity, volume and temperature
  • Automatically averages readings, saving time and tedious hand calculations
  • Easy-to-use - minimal key operation
  • Displays average of readings instantly with the press of a button

    Model 8570 Specifications:

    TEMPERATURE

  • Range: 0 to 200°F (-17.8 to 93.3°C)
  • Accuracy: ±0.5°F (±0.3°C)
  • Resolution: 0.1°F (0.1°C)

    Common Features:

  • Use as IAQ instruments in office or industrial buildings, factories, and warehouses
  • Measure velocity at hoods or HEPA filters
  • Read temperature concurrently with flow
  • Shipped as a kit which includes thermo-anemometer; articulated, telescopic 42-inch probe; 4 C-size batteries; battery eliminator; owner's manual; carrying case and calibration data sheet.

    Common Specifications:

    VELOCITY

  • Range: 20 - 9999 fpm (0.1 - 50 m/s)
  • Accuracy: ±3% rdg. or ±3 fpm, whichever is greater
  • Resolution: 1 fpm (0.01 m/s), 5 fpm = 500 fpm (0.05 m/s = 5.00 m/s)

    VOLUMETRIC FLOW RATE

  • Range: Actual range is a function of maximum velocity and duct size
  • Duct Dimensions: 1 to 250" in increments of 0.1" (1 to 635 cm in increments of 0.1 cm)

    TIME CONSTANT

  • Intervals: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 15, 20, 25, or 30 seconds

    DISPLAY

  • Primary Display: 4-digit LCD, 0.6" (15mm) digit height
  • Secondary Display: 3.5-digit LCD, 0.3" (8mm ) digit height

    PHYSICAL

  • Power Supply: Four "C" size batteries
  • Battery Life: 24 hours average
  • Meter Dimensions: 3.8 x 7.5 x 2.35" (9.65 x 19 x 6 cm)
  • Probe Dimensions: Length: 43.25" (110 cm); Tip Diam.: 0.276" (7.01 mm); Base Diam.: 0.395" (10.03 mm);
  • Knuckle Diam.: 0.377" (9.44 mm)
  • Weight: 1.9 lbs. (0.86 kg)

  • Product Info

    Product Name
    Product Number
    Price $CAN
    Add
    Thermo-Anemometer Kit 85858585 $2348.00 add to basket
    Thermo-Anemometer Kit 85708570 $1417.00 add to basket
    Micro-Printer8928 $470.00 add to basket
    blog comments powered by Disqus