Series 8380 Thermo-Anemometers

Features:

  • Flowrate feature makes simple calculations of volumetric flow rate when the user inputs the duct shape and size, K factor or horn size
  • Velocity measurements are made from the thermal sensor or a Pitot tube
  • Automatic conversion between actual and standard velocity readings
  • Direct calculation of dew point and wet bulb temperature - no psychrometric chart needed (Model 8386 only)
  • Heat flow function calculates heat transferred after a heating or cooling element (Model 8386 only)
  • Stable digital display when measuring fluctuating flow
  • Backlit display is easy to read in poor lighting conditions
  • Switchable from Imperial to metric units via dip switch located on rear of unit (all units shipped reading Imperial units)
  • 40-inch telescoping probe with etched length marks to make duct traverse measurements easier
  • Optional portable printer provides hard copy documentation of your measurements

    DATALOGGING CAPABILITIES

  • Allows user to log 1394 samples with time and date stamp
  • Simultaneously records all parameters available on each model
  • Single point and continuous data logging modes to fit your application
  • Data can be reviewed on-screen, printed or downloaded to a computer spreadsheet program
  • Statistics function displays average, maximum and minimum values, and the number of recorded samples

    Specifications:

    Velocity from Thermal Sensors (all models)

  • Range: 0 to 9,999 fpm (0 to 50 m/s)
  • Accuracy: ±3.0% rdg. ±3 fpm (±.015 m/s), whichever is greater (= 30 fpm)
  • Resolution: 1 fpm (0.01 m/s)

    Velocity from a Pitot Tube (Models 8385 & 8386)

  • Range: 250 to 15,500 fpm (1.27 to 78.7 m/s)
  • Accuracy: ±1.5% at 2,000 fpm (10.06 m/s)
  • Resolution: 1 fpm (0.01 m/s)

    Volumetric Flowrate (all models)

  • Range: Function of max. air velocity, pressure, duct size, and K factor

    Duct Size (all models)

  • Range: 1 to 250" in increments of 0.1" (1 to 635 cm in increments of 0.1 cm)

    Static/Differential Pressure (Models 8385 & 8386)

  • Range: -5 to +15 in.H2O (-1245 to +3735 Pa, or -9.3 to +28 mmHg)
  • Accuracy: ±1% of reading ±0.005 in.H2O (±1 Pa or ±0.01 mmHg)
  • Resolution: 0.001 in.H2O (1 Pa, 0.01 mmHg)

    Temperature

  • Range: 8384 & 8385: 0 to 200°F (-17.8 to 93.3°C)
  • Range: 8386: 14 to 140°F (-10 to 60°C)
  • Accuracy: ±0.5°F (±0.3°C)
  • Resolution: 0.1°F (0.1°C)
  • Relative Humidity (Model 8386 only)
  • Range: 0 to 95% RH
  • Accuracy: ±3% RH
  • Resolution: 0.1% RH

    Wet Bulb Temperature (Model 8386 only)

  • Range: 40 to 140°F (5 to 60°C)
  • Resolution: 0.1°F (0.1°C)
  • Dewpoint (Model 8386 only)
  • Range: 5 to 120°F (-15 to 49°C)
  • Resolution: 0.1°F (0.1°C)

    Heat Flow (Model 8386 only)

  • Range: Function of flow rate, temperature, relative humidity and barometric pressure
  • Measure Available: Sensible Heat Flow, Latent Heat Flow, Total Heat Flow, Sensible Heat Factor
  • Units Measured: BTU/h, kW

    Logging Capability (all models)

  • Range: Up to 1394 samples and 275 test id's (one sample can contain up to all 11 measure ment types)
  • Intervals: 2, 5, 10, 15, 20, 30, 60 sec., 2, 5, 10, 15, 20, 30, 60 min.

    General (all models)

  • Time Constant: 1, 2, ,5, 10, 15, 20 sec. intervals
  • Power Supply: Four AA size batteries
  • Meter Dimensions: 4.2 x 7.2 x 1.5" (10.7 x 18.3 x 3.8 cm)
  • Probe Dimensions: 40" (101.6 cm) L x 0.276" (7.01 mm) dia.
  • Meter Weight: 1.2 lbs. (0.54 kg)

  • Product Info

    Product Name
    Product Number
    Price $CAN
    Add
    Thermo-Anemometer/Data Logger 8384-E-GB8384EGB $1625.00 add to basket
    Thermo-Anemometer/Data Logger 8385-E-GB8385EGB $2070.00 add to basket
    Thermo-Anemometer/Hygrometer/Data Logger 8386-E-GB8386EGB $2377.00 add to basket
    blog comments powered by Disqus

    etool Resource Centre